Mid-sized vibration tester |
- - Model : V8-440 (LDS)
- - Sine force : 60 kN
- - Random force RMS : 66 kN
- - Displacement : 63 mm(p-p)
- - Acceleration : Sine (140 g), Random (50 g r.m.s)
- - Table Size : 900 X 900 mm
|
 |
Vibration measurement and analyzer |
- - Model : LMS SCADAS Mobile SCM01 (SIMENS)
- - Channels : 8 CH
- - Input Frequency Range : (0 ~ 102.4) kHz
- - Dynamic Range : 110 dB
- - Analysis Program S/W : Modal Impact Testing, FFT Analyzer,
Tracked FFT functions, Octave based functions,
Sound Level Meter functions, Order analyzer functions
|
 |
Thermo-hygrostat (Three EA) |
- - Model : PL-4J (ESPEC)
- - Temperature : -40 ℃ ~ 180 ℃
- - Humidity : 20 %R.H. ~ 98%R.H.
- - Deviation : ±0.3 ℃, ±2.5%R.H.
- - Cooling rate : Average 2.0 ℃/min
- - Heating rate : Average 2.0 ℃/min
- - Inside Size : 1,000 X 800 X 1,000 mm (W, D, H)
|
 |
Thermo-hygrostat (Seven EA) |
- - Model : PSL-4J (ESPEC)
- - Temperature : -70 ℃ ~ 180 ℃
- - Humidity : 20 %R.H. ~ 98%R.H
- - Deviation : ±0.3 ℃, ±2.5%R.H.
- - Cooling rate : Average 2.0 ℃/min
- - Heating rate : Average 2.0 ℃/min
- - Inside Size : 1,000 X 800 X 1,000 mm (W, D, H)
|
 |
Accelerated temperature/humidity chamber (Two EA) |
- - Model : EBE-8 (ESPEC)
- - Temperature : -70 ℃ ~ 180 ℃
- - Humidity : 20 %R.H. ~ 98%R.H.
- - Deviation : ±0.3 ℃, ±2.5%R.H.
- - Cooling rate : Average 20.0 ℃/min
- - Heating rate : Average 20.0 ℃/min
- - Cooling rate : Average 10.0 ℃/min
- - Heating rate : Average 10.0 ℃/min
- - Inside Size : 1,000 X 800 X 1,000 mm (W, D, H)
|
 |
Thermal shock chamber(One EA) |
- - Model : TSD-101-W (ESPEC)
- - Temperature : -65 ℃ ~ 300 ℃
- - Recovery Time : Within 5min
- - Inside Size : 700 X 300 X 400 mm (W, D, H)
|
 |
Thermal shock chamber (One EA) |
- - Model : TSA-1100HS (ESPEC)
- - Temperature : -65 ℃ ~ 180 ℃
- - Recovery Time : Within 5min
- - Inside Size : 1,000 X 1,000 X 1,100m (W, D, H)
|
 |
Medium/large room chamber (Two EA) |
- - Model : EBE-2EW6P2E4F_38M (ESPEC) EBE-8E30W6P2T4L_38M (ESPEC)
- - Temperature : -60 ℃ ~ 100 ℃
- - Humidity : 10 %R.H. ~ 98%R.H.
- - Deviation : ±0.3 ℃, ±4.5%R.H.
- - Cooling rate : Average 1.0 ℃/min
- - Heating rate : Average 1.0 ℃/min
- - Inside Size : 2,000 X 2,000 X 2,000 mm (W, D, H)
4,000 X 4,000 X 3,500 mm (W, D, H)
|
 |
Altitude tester (One EA) |
- - Model : MAT-1000 (Terdny)
- - Temperature : -70 ℃ ~ 150 ℃
- - Pressure : Normal ~ 0.5 kPa
- - Feet : Normal ~ 130,000
- - Deviation : ≤±2kPa (≥40kpa)
≤±5% (2 ~40kpa)
- - Inside Size : 1,000 X 1,000 X 1,000 mm (W, D, H)
|
 |
Dust tester (Two EA) |
- - Model : P14.46 (PLT)
- - Vacuum : -20 mbar
- - Talcum : 2 kg/㎥
- - IP : 5X, 6X
- - Inside Size : 700 X 300 X 700 mm (W, D, H)
- - Inside Size : 2,000 X 2,000 X 2,500 mm (W, D, H)
|
 |
Spray and rain tester (One EA) |
- - Model : Spray and rain tester (KTR)
- - IP : X1, 2, 3, 4, 5, 6, 6K, 7, 9K
- - Rotation angle : ±60˚, ±180˚ (X3, X4)
- - Test time: At least three minutes ~ 10 minutes
- - Quantity of flow for test : 12.5L/min (X5), 100L/min (X6)
|
 |
Acceleration tester (One EA) |
- - Model : Acceleration tester (GU)
- - Maximum acceleration : 100 g
- - Maximum load : 150 kg
- - Slip ring : 24 ch, 2A/ch, AC, DC available
- - Arm Size : 1,500 mm
- - Table Size : 800 X 800 mm
|
 |
Slope tester (One EA) |
- - Model : Slope tester (Sejong F.A)
- - Slope : Maximum section (25˚), maximum front (50˚)
- - Maximum load: 1.5 ton
- - Speed ??control: Able to set time for one round trip
- - Table Size : 1,200 X 1,200 mm
|
 |
Drop tester (One EA) |
- - Model: Drop Tester (Neuron Pit Co., Ltd.)
- - Test height : 300 ~ 1 800 mm
- - Maximum load : 60 kg
- - Height control: Manual
- - Control of the dropping method : Manual (edge, floor, etc.)
- - Floor board size : 1 200 X 1 500 mm
|
 |
Sand dust tester (1 EA) |
- - Model : Sand dust tester (AIR DYNAMICS (USA))
- - Test temperature : 23 ℃ ~ 70 ℃
- - AIR VELOCITY : Land (1.5 ± 1) to (8.9 ± 1.3) m/s
Sand (18 ~ 29) m / s
- - Switch : 360° rotatable
- - External size : 3Ⅹ 6.8 Ⅹ 4.5 m (W, D, H)
- - Internal size : 1,000Ⅹ 1,000 Ⅹ 1,00 mm (W, D, H)
|
 |
Rainfall tester (One EA) |
- - Model : Rainfall tester (KTR (Korea))
- - MIL-STD-810 : Procedure 1, procedure 2, procedure 3
- - DO-160 : Drip proof test
- - Max EUT SIZE : 1.5 Ⅹ 1.5 Ⅹ 1.5 m (W,D,H)
- - Wind speed : 18 m/s
- - Test temperature : 23 ℃ ~ 70 ℃
- - Bottom of the chamber : Sample rotation table
|
 |
Pulse generator |
- - Model : M-CS115 / POG-CS116-6
- - Charging Voltage : 2 kV / 15 kV
- - Pulse Width : 30 ns (CS115)
- - Frequency : 10 kHz ~ 100 MHz (CS116)
- - Size : 630 mm x 530 mm x 485 mm
- - Weight : 34.5 kg
|
 |
E-field generator |
- - Model : EFG-03
- - Frequency : 10 kHz ~ 100 MHz
- - Power Handling 3.5 kW
- - Impedance : 50 ohms nominal
- - Element Dimensions : 87 cm x 155 cm
- - Height Adjustment : 122 cm
- - Weight : 68 kg
- - Input Connector : 7/16 female
- - Cooling : Not Required
|
 |
Broadband antenna with large output |
- - Model : HPBA-2510
- - Frequency : 25 MHz ~ 100 MHz
- - VSWR : 2.5:1 average
- - Polarization : Linear
- - Power Handling : 3.5 kW
- - Feedpoint Impedance : 50 ohms nominal
- - Weight : 9.1 kg
- - RF Connector : 7/16 female
|
 |
Lightning induction tester |
- - Indirect lightning tester
- - Multiple Stroke Generator: indirect lightning test on aircraft: Multiple Stroke (MS). WF1 & WF4 (6.4/70μμs); WF5A (40/120μμs); WF5B (50/500μs) up to 24 pulses.
- - Single Stroke Generator : Generator for indirect lightning test on aircraft Single stroke (SS). WF1 (6.4/70μs) 250A up to 4000A, WF4: (6.4/70μs) 125V up to 3200V and WF5A: (40/120μs) 400A up to 6000A.
- - Multiple Burst Generator : Generator for indirect lightning tests : PIN injection W3, 1MHz, Level 3, cable bundle WF3: 1MHz, 10MHz up to Level3, WF2: 0.1/6.4μs up to level 5. Multiple burst WF3 1MHz and 10MHz up to Level 5.
- - Oscillatory Multiple Burst Generator + EXT : 4 Unit High mainframe for one NWlWFxxxxFS (first stroke) and one NW WFx xxx SS module with connections to generator OS MB. Controlled by the generator
|
 |
V-Log periodic antenna |
- - Model : VAL-8001
- - Frequency : 80 MHz ~ 1 GHz
- - Gain : 8 dBi
- - VSWR : 1.5:1 average
- - Polarization : Linear
- - 3 dB Beam Width : 65 degrees
- - Power Handling : 1 kW
- - Impedance : 50 ohms nominal
|
 |
EMP pulse generator |
- - Model : EMP80K-5/500
- - Peak Open Circuit Voltage : 10 kV ~ 80 kV
- - Source Impedance : > 60 ohm
- - Peak Short Circuit Current : > 1 kA
- - Pulse Shape : Double exponential waveform
- - Rise Time : < 20 ns
- - Pulse Width : 500 ns ~ 550 ns
- - Weight : 80 kg
|
 |
EMP pulse generator |
- - Model : EMP300K-5/500
- - Peak Open Circuit Voltage : 100 kV ~ 350 kV
- - Source Impedance : > 60 ohm
- - Peak Short Circuit Current : 1.5 kA ~ 6.0 kA
- - Pulse Shape : Double exponential waveform
- - Rise Time : < 20 ns
- - Pulse Width : 500 ~ 550 ns
- - Weight : 175 kg
|
 |
Mold testing chamber (Four EA) |
- - Inner dimension
850 x 850 x 850 mm (W, D, H)
- - Temperature range : (5 ~ 70) ℃ ± 1.0 ℃
- - Humidity range : (30 ~ 98) % R.H. ± 2.0 % R.H.
- - Air velocity : (0.5 ~ 1.0) meters/second
|
 |
Fluid contamination (Forced convection oven, one EA) |
- - Model: Forced convection oven
- - Test temperature : 23 ℃ ~ 250 ℃
- - External size : 577Ⅹ 642 Ⅹ 760 mm (W, D, H)
- - Internal size : 400Ⅹ 360 Ⅹ 420 mm (W, D, H)
|
 |
Salt spray chamber |
- - Chamber Capability : 2000 L
- - Chamber Internal Dimension : 2,160 mm X 980 mm X 1,320 mm
- - Temperature range : -40 ℃ ~ 70 ℃
- - Humidity range : (20 - 100) % R.H.
- - Mode of Operation : Salt Spray, Dry, Humidity, Controlled Humidity & Temperature
|

Radiographic test(RT)

Ultrasonic test(UT)

Penetration test(PT)
|
Nondestructive test |
- - MIL-STD-2175, MIL-STD-1907, AMS-STD-2175, AMS-A-21180
- - Test range: Radiographic test(RT), Ultrasonic test(UT), Magnetic particle test(MT), liquid penetration test(PT)
- - X-ray generator: (140 ~ 300) kV. 5mA
|
 |
Semi-anechoic room(One EA) |
- - Size : 9.8 m × 6.2 m × 7.4 m (W × D × H)
- - Ambient noise : 7.5 dB(A)
- - Low cut-off frequency : 63 Hz
|
Frequency analyzer (acoustic, vibration analysis, 2 EA) |
- - Model : 3050-A-060
- - 6 Input channels
- - 6.3 Hz to 20 kHz input range
- - Sound Power Level(PWL), Sound Pressure Level(SPL)
- - FFT, CPB octave analysis
|